  • FEATURE

    Complete Intellectual Design

    Automatic Exposure Control (AEC) detects the lacteal gland area with precision and controls the tube voltage and the mAs value automatically.

     

    Flexible automatic compression makes it possible to automatically adjust the compression force on the breast to an appropriate value, which makes it possible to improve patient comfort.

    Optimal Image Quality  

    In order to obtain high resolution image at lower dose, a variety of characteristic curves were validated by clinical which were assembled to enhance the contrast grade and reduce the impulse noise of image, this is the best way for mammary screening.

    -font-kerning:1.0000pt;" >

     

    Flexible automatic compression makes it possible to automatically adjust the compression force on the breast to an appropriate value, which makes it possible to improve patient comfort.

    Prospective X-ray Tube Technology with Tungsten Target    

    l High X-ray energy

    l Strong penetrability

    l Low dose, high quality image

    l Trend of mammography technology

    New Generation of Flat Panel Detector (FPD)

    l 240 mm × 300 mm, full-field FPD

    l High limiting resolution

    l Wide  dynamic range

    l Low dose

    Isocentric Rotation

    Full of humanity designdowny lines as well as smooth the appearance of this Digital Mammography even more warmth.

    The examination position was the center of rotation, which is a  Ergonomically Designed and fully meet the requirements of clinical breast examination.

    -kerning:1.0000pt;" >Flexible automatic compression makes it possible to automatically adjust the compression force on the breast to an appropriate value, which makes it possible to improve patient comfort.

    One Key in Position

    C-Arm automatic motion to preset position by one button and would auto-stop.

    Indicate lamp automatically illuminates, eliminating the need for a separate power switch, very easy to control and also with user friendly design.Friendly Software Interface

     

    Friendly Software Interface

    The software possesses of friendly interface and strong ability of human-computer interaction.

    Configuration: including system, study and user management. Especially the configuration for work list and storage

    In order to get a high quality image, some parameters were provided for user to adjust.

    MAIN PART

    Main Unit

    Flat Panel Detector

    High Voltage Generator

    X ray Tube Assembly

    Collimator

    Image Workstation

     

    SPECIFICATION

    Flat Panel Detector: FPD400

    Pixel Area: 24 cm × 30 cm

    Receptor Type: Amorphous Silicon

    Pixel Pitch: 85 μm

    Image Preview: 9s

    Image Time(including Processing): 10s

    Limiting Resolution: 6 lp/mmNominal data
    7 lp/mmTypical value

    A/D Conversion: 14 bit

    Pixel Matrix: 3528 × 2816

    Data Output: Gigabit Ethernet

    Weight: 3.8 kg

     

    High Voltage Generator: VMX40P5X4297

    Nominal Mains Voltage: 200-240 V AC

    Output Power: 5 kW

    mA Range: 10 ~ 160 mA

    kV Range: 20 ~ 40 kV

    mAs Range: 2.5 ~ 630 mAs

    ms Range: 16 ~ 10000 ms

    Autocorrection: YES

    Error Log: YES

    Automatic Overload Protection: YES

     

    X-ray Tube: C339V(XM15T)

    Maximum Tube Current: 160 mA

    Focal Spot: Small Focus: 0.1 mm
    Large Focus: 0.3 mm

    Anode Angle : 15°

    Anode Marerial: RT-TZM/tungsten target

    Anode Speed: 10000 rpm

    Input Energy(at 0.1s) Small Focus: 4 kW
    Large Focus: 16 kW

    Operating Tube Voltage: 20 ~ 49 kV

    Anode Heat Storage Capacity: 300 Khu

     

    C-Arm

    C-Arm Rotation Mode: Motor, 10°/s

    C-Arm Rotation Range:  -165°~+180°

    C-Arm Vertical motion Mode: Motor, 35 mm/s

    C-Arm Vertical motion Range: 65~140 cm

    Armrests that provide the sense of security are mounted so as to decrease patient's unpleasantness at the positioning.

     

    Compression Plate

    Compression Plate Vertical motion Mode: Motor: 20 mm/s
    Manual: 10 mm/s

    Compression Plate Vertical motion Range:≥25 cm

    Foot switch: 2

    Compression Plate Release Modes: Full-anto Release/Emergency  Release/Foot Switch Release/Manual Release

    Compression Modes: Flexible Compression

     

    X ray Collimator

    Illumination:≥160 LUX(SID=65 cm)

    Light Source Delay Time: 30 s

     

    Grid

    Interspacer Marerial: Carbon Fiber

    Cover Plate Marerial: Carbon Fiber

    Focal Length: 65 cm

    Aspect Ratio : 51

    Line Density: 41 L/cm

    Size: 246 mm × 338 mm

     

    External Dimension

    External Dimension(Length × Width × Height) : 660 mm × 945 mm × 2030 mm

     

    Call Intercom System

    Automatic Playback: YES

    Voice Talkback: YES

    Recording: YES

     

    Software System

    Image Browser: Image selection, image processing (crop, zoom, grayscale adjustment, rotate, flip, tag, window layout etc.)

    Image Post-Processing: Image enhancement, tissue equalization, noise reduction, gray level stretching

    Image Output: Support for Laser printer output, laser camera output, Dicom interface and hard disk

    Data Management: Data deletion, statistics, edit, backup and restore

    Other features: Detector calibration procedures, failure report function, worklist module, dynamic password maintenance, machine using period limiting setting ,report writing and printing etc.

     

    PC System

    Display: Lenovo LCD, LT1953wA, 19inch

    CPU:≥Intel Core i3-3240

    RAM: 4GB DDR3

    Hard Disk: 500GB

    Graphics card: Integrated graphics card

    CD-ROM: DVD-R/W

    Net Card: 100/1000Mbits NIC

    USB: 6 USB 2.0

    Extend: 2PCI+1PCIE+1PCIE*16

    OS: WINDOWS 7 32bit

Reviews

Write a review

AJ-MO80     Full Digital Mammography X-Ray Machine

AJ-MO80 Full Digital Mammography X-Ray Machine

Complete Intellectual Design

Automatic Exposure Control (AEC) detects the lacteal gland area with precision and controls the tube voltage and the mAs value automatically.

 

30 autres produits dans la même categorie:

  • support service

    Lorem ipsum dolor sit amet conse ctetur voluptate velit esse cillum dolo

  • free delivery

    Lorem ipsum dolor sit amet conse ctetur voluptate velit esse cillum dolo

  • secure payment

    Lorem ipsum dolor sit amet conse ctetur voluptate velit esse cillum dolo